Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Rev. bras. oftalmol ; 81: e0006, 2022. tab, graf
Artigo em Português | LILACS | ID: biblio-1360917

RESUMO

RESUMO Objetivo: Identificar se há mudança refracional significativa após realização de capsulotomia posterior com laser Nd:YAG em olhos pseudofácicos. Métodos: Estudo retrospectivo com análise de prontuários de pacientes atendidos em um hospital com diagnóstico de opacificação de cápsula posterior do cristalino tratada com capsulotomia posterior com laser Nd:YAG no período de outubro de 2019 a março de 2021. A comparação entre a refração antes e após o procedimento foi realizada calculando-se o equivalente esférico. Também foi avaliada a mudança da acuidade visual, aferida por LogMAR. Resultados: Foram analisados 90 prontuários, totalizando 140 olhos, de pacientes submetidos à capsulotomia posterior com laser Nd:YAG. O equivalente esférico médio pré-procedimento foi de -0,07±0,89D, mínimo de -3,0D e máximo de +2,5D, mediana (intervalo interquartil) de 0,0D (-0,50D a +0,375D). A média pós-procedimento foi de -0,18±0,86D, mínimo de -3,5D e máximo de +2,25D, mediana (intervalo interquartil) de -0,125D (-0,50D a 0,0D). com p<0,0082. Dos 140 olhos, 66 sofreram miopização e 37 hipermetropização. A média de alteração do equivalente esférico geral foi de -0,12±0,51D, mínimo de -2,50D e máximo de +1,25D, mediana (intervalo interquartil) de 0,0D (-0,375D a +0,125D). Ao se comparar a diferença entre o equivalente esférico antes e após o procedimento do grupo de olhos que sofreu miopização (n=66) ou hipermetropização (n=37), separadamente, ambos obtiveram p<0,0001. Ao se compararem todos os olhos que sofreram alguma alteração refracional (n=103), foi encontrado p=0,008. A acuidade visual média pré-procedimento foi de 0,23±0,32, mínimo de 0,0 e máximo de 2,3. Pós-procedimento, a média foi de 0,06±0,13, mínimo de -0,12 e máximo de 0,7, com p<0,0001. Conclusão: A capsulotomia posterior com laser Nd:YAG gerou melhora significativa da acuidade visual nos pacientes do estudo, porém também gerou alteração refracional significativa após o procedimento, tanto para miopização (a mais frequente), quanto para hipermetropização.


ABSTRACT Objective: To identify if there is a significant change on refraction after Nd:YAG laser posterior capsulotomy in pseudophakic eyes. Methods: A retrospective study with analysis of medical records of patients treated at a hospital, with diagnosis of opacification of posterior lens capsule treated with Nd:YAG laser posterior capsulotomy, from October 2019 to March 2021. The comparison of refraction before and after the procedure was performed by calculating the spherical equivalent. Changes in visual acuity (VA), measured by LogMAR, were also evaluated. Results: A total of 90 medical records (140 eyes) of patients submitted to Nd:YAG laser posterior capsulotomy were analysed. The mean pre-procedure spherical equivalent was -0.07±0.89D, minimum of -3.0D and maximum of +2.5D, median (interquartile range) of 0.0D (-0.50D to +0.375D). The post-procedure mean was -0.18±0.86D, minimum of -3.5D and maximum of +2.25D, median (interquartile range) of -0.125D (-0.50D to 0.0D), with p <0.0082. Of the 140 eyes, 66 underwent myopia and 37 hyperopia, the mean change in the general spherical equivalent was -0.12±0.51D, minimum -2.50D and maximum +1.25D, median (interquartile range) of 0.0D (-0.375D to +0.125D). When comparing the difference between the spherical equivalent before and after the procedure of the group of eyes that underwent myopia (n=66) or hyperopia (n=37), separately, both obtained p<0.0001. When comparing all eyes that suffered any change on refraction (n=103), the p value was 0.008. The mean pre-procedure visual acuity was 0.23±0.32, minimum of 0.0 and maximum of 2.3. After the procedure, the mean was 0.06±0.13, minimum of -0.12 and maximum of 0.7, p<0.0001. Conclusion: Nd:YAG laser posterior capsulotomy significantly improved visual acuity of patients in this study; however, it also led to a significant change on refraction after the procedure, both for myopization, which was more frequent, and for hyperopization.


Assuntos
Humanos , Masculino , Feminino , Idoso , Refração Ocular , Lasers de Estado Sólido/uso terapêutico , Capsulotomia Posterior/efeitos adversos , Capsulotomia Posterior/métodos , Extração de Catarata/efeitos adversos , Prontuários Médicos , Estudos Retrospectivos , Facoemulsificação/efeitos adversos , Pseudofacia/cirurgia , Terapia a Laser/métodos , Opacificação da Cápsula/cirurgia , Opacificação da Cápsula/etiologia
2.
Journal of Central South University(Medical Sciences) ; (12): 1754-1762, 2022.
Artigo em Inglês | WPRIM | ID: wpr-971361

RESUMO

Posterior capsule opacification (PCO), a common complication after cataract surgery, impacts a patient's long-term visual quality to various degrees. Although a neodymium:yttrium aluminum garnet (Nd:YAG) laser posterior capsulotomy is a very effective treatment, it may lead to a serial of complications. Accordingly, the search for simple, safe, and effective methods to prevent PCO has received widespread attention. Various researchers are committed to the interdisciplinary collaboration between medicine and engineering fields, such as functionalizing the surface of the intraocular lens (IOL) via supercritical fluid impregnation, coating the surface of the IOL, high-concentration drug immersion, and application of a drug delivery system, to effectively reduce the incidence and severity of PCO.


Assuntos
Humanos , Opacificação da Cápsula/cirurgia , Implante de Lente Intraocular , Catarata/etiologia , Cápsula do Cristalino/cirurgia , Lentes Intraoculares/efeitos adversos , Resultado do Tratamento , Complicações Pós-Operatórias , Desenho de Prótese
3.
West Afr. j. med ; 39(11): 1174-1179, 2022. tales, figures
Artigo em Inglês | AIM | ID: biblio-1410939

RESUMO

BACKGROUND: PCO occurs commonly postoperatively followingcataract extraction in children, obscuring vision as did the initialcataract. It may require a second surgical procedure when it is dense.It is expected that this results in restoration of vision and it is importantto ascertain that this is the case as well as to examine any significantchanges in refraction thereafter.M ETHODS: A retrospective observational study extractingdemographic and clinical information from case notes of patients whohad membranectomy and/or capsule polishing between October 2017and September 2018.RESULTS: 57 eyes of 51 patients were enrolled. There was a 2:1male: female ratio. Mean age at cataract surgery was 6.33 3.59yearswhilst that for PCO surgery was 9.68 3.89years. Postoperativevisual acuity (by WHO definition) was good (between 6/6 and 6/18)in 33.3%, compared to 8.8% preoperatively. Whereas presenting visualacuity was poor (<6/60) in 61.4% preoperatively, this reduced to30% postoperatively. Visual outcome was influenced by age at cataractsurgery, age at PCO surgery, interval between cataract and PCO surgeryand type of cataract. Children >8 years of age at time of PCO surgeryhad a greater proportion of good post-operative best corrected visualacuity (BCVA) (52.6%), whilst 75% of children younger than 8yearsat time of surgery turned out with poor BCVA after surgery.Developmental cataracts proportionately had the best outcome ofvisual acuity. There was a range of refractive shift of +0.25D to ­5.25D with a mean myopic shift of ­1.51D following membranectomy. CONCLUSION: There was a good proportion of children withsignificant improvement in visual acuity on the short term,and a mildmyopic shift following membranectomy.


Assuntos
Humanos , Criança , Avaliação de Resultados em Cuidados de Saúde , Cápsula Posterior do Cristalino , Catarata , Opacificação da Cápsula , Centros de Atenção Terciária
5.
Rev. bras. oftalmol ; 79(1): 42-45, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1092659

RESUMO

Abstract Purpose: To determine the impact of neodymium:YAG (Nd:YAG) laser posterior capsulotomy on quality of life and visual acuity in adults. Methods: A prospective study that included patients over 65 years old with clinical indications for Nd: YAG laser capsulotomy. On the day of the procedure, corrected distance visual acuity tests, slit-lamp examination and posterior capsule opacification (PCO) photo documentation were performed, followed by application of the National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). The PCO rate was evaluated with Evaluation of Posterior Capsule opacification (EPCO 2000) software. Four weeks after the posterior capsulotomy, corrected distance visual acuity was measured, and the NEI-VFQ-25 was applied again. Complications were also reported. Results : Sixty eyes from 45 patients were enrolled in the study. The mean age was 71.51 ± 6.38 years (65 to 93). Comparing the results before and after the Nd:YAG laser capsulotomy, there was a statistically significant improvement in quality of life according to the NEI-VFQ-25 (p<0.001) and in visual acuity (p=0.0). The mean score in NEI-VFQ-25 Questionnaire before capsulotomy was 62.07 ± 20.90 (16.81-95.90) and after was 83.95±19.49 (20.68 - 100.0). The mean CDVA before the procedure was 0.75 ± 0.35 LogMAR (0.1-1.3) and after was 0.21 ± 0.20 LogMAR (0.0-1.3). The mean PCO rate measured by the EPCO software was 0.688 ± 0.449. There was a positive correlation between the EPCO score and the total score of quality of life after Nd: YAG laser capsulotomy (r=0.845, p=0.00). Damage to intraocular lens was the only complication observed in six eyes (10%). Conclusion: Nd: YAG laser capsulotomy, in addition to improving visual acuity, is able to improve quality of life.


Resumo Objetivo: Determinar o impacto da capsulotomia posterior com laser de neodímio: YAG (Nd: YAG) na qualidade de vida e na acuidade visual em adultos. Métodos: Estudo prospectivo que incluiu pacientes acima de 65 anos com indicação clínica para capsulotomia com laser de Nd: YAG. No dia do procedimento, foram realizados testes de acuidade visual corrigida, exame com lâmpada de fenda e fotodocumentação da opacificação da cápsula posterior (OCP), seguido da aplicação do National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). A taxa de OCP foi avaliada utilizando o software de avaliação de opacificação de cápsula posterior (EPCO 2000). Quatro semanas após a capsulotomia posterior, a acuidade visual corrigida foi medida, e o NEI-VFQ-25 foi aplicado novamente. Complicações também foram relatadas. Resultados: Sessenta olhos de 45 pacientes foram incluídos no estudo. A idade média foi de 71,51±6,38 anos (65 to 93). Comparando os resultados antes e após a capsulotomia com laser Nd: YAG, houve melhora estatisticamente significante na qualidade de vida de acordo com o NEI-VFQ-25 (p <0,001) e na acuidade visual (p = 0,0). A média do escore total do questionário NEI-VFQ-25 pré capsulotomia foi de 62.07 ± 20.90 (16.81-95.90) e pós foi de 83.95 ±19.49 (20.68 - 100.0). A AVCC antes do procedimento foi 0.75 ± 0.35 LogMAR (0.1-1.3) e após foi 0.21 ± 0.20 LogMAR (0.0-1.3). A taxa média de OCP medida pelo software EPCO foi de 0,688 ± 0,449. Houve correlação positiva entre o escore EPCO e o escore total de qualidade de vida após a capsulotomia com laser de Nd: YAG (r = 0,845, p = 0,00). O dano à lente intraocular foi a única complicação observada em seis olhos (10%). Conclusão: A capsulotomia com laser Nd: YAG, além de melhorar a acuidade visual, é capaz de melhorar a qualidade de vida.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Qualidade de Vida , Opacificação da Cápsula/cirurgia , Capsulotomia Posterior/psicologia , Extração de Catarata , Acuidade Visual , Estudos Prospectivos , Inquéritos e Questionários , Implante de Lente Intraocular , Terapia a Laser/métodos , Lasers de Estado Sólido , Cápsula Posterior do Cristalino/cirurgia , Cápsula Posterior do Cristalino/patologia , Capsulotomia Posterior/métodos , Lentes Intraoculares , Neodímio
6.
Clinics ; 75: e1604, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1133462

RESUMO

OBJECTIVE: To compare the effects of hydrophobic and hydrophilic materials in square-edged acrylic intraocular lenses (IOLs) on the development of posterior capsule opacification (PCO) after pediatric cataract surgery. METHODS: Patients were randomly assigned to group 1 (hydrophobic acrylic square-edged IOLs; 13 eyes) or group 2 (hydrophilic acrylic square-edged IOLs; 13 eyes). The study evaluated PCO rates using Evaluation of Posterior Capsule Opacification (EPCO) 2000 software at one, three, six and 12 months postoperatively. Postoperative measurements also included corrected distance visual acuity (CDVA), neodymium:yttrium‐aluminum‐garnet (Nd:YAG) capsulotomy and postoperative complications other than PCO. RESULTS: Both groups had significant increases in PCO rates after one year. Comparison of the groups showed no significant differences in the EPCO scores at three (group 1, 0.007±0.016 vs group 2, 0.008±0.014; p=0.830), six (group 1, 0.062±0.103 vs group 2, 0.021±0.023; p=0.184), or twelve months postoperatively (group 1, 0.200±0.193 vs group 2, 0.192±0.138; p=0.902). We also found no significant group differences regarding the change (delta, Δ) in EPCO scores between three and six months (group 1, 0.055±0.09 vs group 2, 0.013±0.02; p=0.113) or between six and twelve months postoperatively (group 1, 0.139±0.14 vs group 2, 0.171±0.14; p=0.567). Twenty-three percent of patients required Nd:YAG capsulotomy at the twelve-month visit. CONCLUSIONS: No differences in PCO rates were found between hydrophobic and hydrophilic acrylic square-edged IOLs in children between five and twelve years of age at one year of follow-up.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Catarata , Opacificação da Cápsula , Lentes Intraoculares , Complicações Pós-Operatórias , Desenho de Prótese , Resinas Acrílicas , Estudos Prospectivos , Facoemulsificação , Implante de Lente Intraocular
7.
Arq. bras. oftalmol ; 82(3): 189-194, May-June 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001312

RESUMO

ABSTRACT Purpose: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. Methods: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. Results: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. Conclusions: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


RESUMO Objetivo: Avaliar objetivamente a qualidade da visão óptica antes e depois da capsulotomia com Nd: YAG, obtida por imagem pelo metodo de dupla passagem de luz em pacientes com opacificação capsular posterior. Método: Análise retrospectiva de 26 olhos pseudofácicos com opacificação capsular posterior visualmente significativa, que foram submetidos à capsulotomia de Nd: YAG. O índice de dispersão objetiva, a função de transferência de modulação, a relação de Strehl e a acuidade visual à distância corrigida foram avaliados antes e após a capsulotomia com YAG usando o dupla passagem de luz (OQAS II, Visiometrics, Espanha). Também foi analisado um subgrupo de pacientes com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (20/25) ou melhor. Resultados: Os índices de qualidade da visão melhoraram em todos os 26 olhos, resultando em uma melhora estatisticamente significativa na acuidade visual à distância corrigida (p=0,007), índice de dispersão objetiva (p=0,001), função de transferência de modulação (p=0,001) e relação de Strehl (p=0,020). A melhora média na acuidade visual à distância corrigida foi de 0,12 ± 0,04 logMAR, no índice de dispersão objetiva foi de 2,84 ± 0,76, no função de transferência de modulação foi de 12,29 ± 2,77 e na razão de Strehl foi de 0,06 ± 0,03 em todos os olhos. Sub-análise de 10 olhos com 0.10 logMAR (20/25) acuidade visual à distância corrigida ou melhor também mostrou uma melhora estatisticamente significativa no índice de dispersão objetiva (p=0,001). A melhora média no OSI foi de 0,76 ± 16, uma diminuição de 35% na dispersão da luz intraocular. Conclusões: A qualidade da visão avaliada pelo dupla passagem de luz mostra uma melhora significativa nas medidas objetivas da qualidade da visão após a capsulotomia do YAG. O índice de dispersão objetiva melhora após a capsulotomia YAG, mesmo em olhos com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (Snellen 20/25) ou melhor.


Assuntos
Humanos , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Opacificação da Cápsula/fisiopatologia , Capsulotomia Posterior/reabilitação , Valores de Referência , Retina/fisiopatologia , Retina/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Pseudofacia/diagnóstico por imagem , Lasers de Estado Sólido/uso terapêutico , Opacificação da Cápsula/diagnóstico por imagem , Capsulotomia Posterior/métodos
8.
Korean Journal of Ophthalmology ; : 222-227, 2019.
Artigo em Inglês | WPRIM | ID: wpr-760030

RESUMO

PURPOSE: To investigate the rate of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy in the hydroimplantation intraocular lens (IOL) technique. METHODS: This retrospective study was comprised of 6,192 eyes in 3,790 patients who underwent surgery from January 2013 to September 2017 and then were followed up for at least 1 year. The eyes of these patients were divided into two groups: either viscoimplantation or hydroimplantation. The follow-up examinations were carried out on the 1st day, 4th day, 1st month, and 3 months to 1 year postoperatively. The Nd:YAG capsulotomy rates were evaluated by the different IOL implantation techniques and IOL materials. RESULTS: The mean follow-up duration of the patients was in the viscoimplantation group 14.85 ± 2.43 and 15.05 ± 1.93 months in the hydroimplantation group. The Nd:YAG capsulotomy rate was significantly lower in the hydroimplantation group compared with the viscoimplantation group for the entire hydrophilic IOL model (p < 0.001). In addition, the Nd:YAG rate was lower in the hydroimplantation group that used a hydrophilic IOL than it was in the viscoimplantation group, which used a hydrophobic IOL. CONCLUSIONS: The hydroimplantation technique reduced the Nd:YAG capsulotomy rate.


Assuntos
Humanos , Alumínio , Opacificação da Cápsula , Seguimentos , Implante de Lente Intraocular , Lentes Intraoculares , Capsulotomia Posterior , Estudos Retrospectivos , Ítrio
9.
Journal of the Korean Ophthalmological Society ; : 152-159, 2019.
Artigo em Coreano | WPRIM | ID: wpr-738602

RESUMO

PURPOSE: To evaluate the efficacy and safety of pars plana posterior capsulectomy (PPPC) during phacovitrectomy. METHODS: In this retrospective study, 76 patients (76 eyes) who underwent phacovitrectomy were enrolled. The patients were divided into two groups according to whether PPPC was performed during phacovitrectomy. In group A, PPPC using a vitreous cutter was combined with phacovitrectomy; in group B, only phacovitrectomy was performed. The best-corrected visual acuity (BCVA), predicted and actual refractive errors, adverse events, and posterior capsular opacity (PCO) were analyzed and compared between the two groups. RESULTS: Age, sex, and pre- and postoperative BCVA were not significantly different between group A (n = 37) and group B (n = 39). No intraoperative complications were identified in either group. In group A, the actual refraction (postoperative 2 months) was −0.44 ± 0.88 diopters (D) and a mild hyperopic shift was found compared to the preoperative predicted refraction (−0.56 ± 0.40 D). In group B, the actual refraction was −0.70 ± 0.72 D and a mild myopic shift was found compared to the preoperative predicted refraction (−0.60 ± 0.81 D). The difference in refraction shifts between the two groups was not significant but very close to it (p = 0.050). In group A, yttrium-aluminum-garnet (YAG) laser posterior capsulotomy was not required. However, PCO was observed in 10 eyes in group B, 6 of which subsequently underwent YAG laser posterior capsulotomy at the last follow-up. Lens instability such as dislocation or subluxations was not observed during the follow-up period. CONCLUSIONS: PPPC combined with phacovitrectomy may lead to hyperopic refractive changes. However, this was a safe and effective approach to prevent PCO and additional YAG laser posterior capsulotomy.


Assuntos
Humanos , Opacificação da Cápsula , Luxações Articulares , Seguimentos , Complicações Intraoperatórias , Lasers de Estado Sólido , Facoemulsificação , Capsulotomia Posterior , Erros de Refração , Estudos Retrospectivos , Acuidade Visual , Vitrectomia
10.
Clinics ; 72(9): 543-546, Sept. 2017. tab
Artigo em Inglês | LILACS | ID: biblio-890729

RESUMO

OBJECTIVE: To evaluate the efficiency of long-term cataract surgery using low-cost intraocular lens implantation in community campaigns. METHODS: Fifty-eight randomly selected patients were evaluated four years after phacoemulsification and Ioflex intraocular lens implantation. Causes of low visual acuity related to the intraocular lens were evaluated, and treatment costs were calculated. RESULTS: The mean age of patients was 72±10.2 years. Four years after surgery, 25 eyes (43.0%) had decreased visual acuity related to the intraocular lens: posterior capsule opacification was noted in 24 eyes (41.3%), and intraocular lens opacification was noted in one eye (1.7%). The total cost of the post-surgical complication treatments represented 6.3% of the initial budget of the entire surgical patient group. CONCLUSIONS: The efficiency of cataract surgery with low-cost Ioflex intraocular lens implantation was significantly reduced in a long-term follow-up study because postoperative complications related to intraocular lenses emerged at higher rates than when the gold-standard treatment was used.


Assuntos
Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Resinas Acrílicas/economia , Resinas Acrílicas/uso terapêutico , Implante de Lente Intraocular/métodos , Lentes Intraoculares/economia , Facoemulsificação/métodos , Opacificação da Cápsula/etiologia , Custos e Análise de Custo , Seguimentos , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/economia , Lentes Intraoculares/efeitos adversos , Facoemulsificação/efeitos adversos , Facoemulsificação/economia , Complicações Pós-Operatórias , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
11.
Rev. bras. oftalmol ; 76(4): 186-189, July-Aug. 2017.
Artigo em Inglês | LILACS | ID: biblio-899075

RESUMO

Abstract Objective: The aim of this study is to examine the effect of Nd: YAG laser capsulotomy on refraction, central macular thickness (CMT) and retinal nerve fiber layer (RNFL) thickness. Methods: 42 eyes of 42 patients who treated with Nd:YAG laser capsulotomy were included in thisprospective study. Spherical equivalent (SE), cyclindrical power refraction, CMT and RNFL thickness were evaluated preoperatively and at postoperative first day, first week and postoperative first month. Results: Spherical equivalent values and central macular thickness values did not significantly change in the first month after treatment. Average and nasal retinal nerve fiber layer thickness values significantly increase and cyclindrical power refraction significantly decreased during the visits. Conclusion: Nd:YAG laser capsulotomy is confident and reliable treatment option of the posterior capsula opacification (PCO). After Nd: yag laser capsulotomy cyclindrical power refraction and RNFL thickness values significantly change.


Resumo Objetivo: O objetivo deste estudo é examinar o efeito da capsulotomia de laser Nd: YAG na refração, espessura macular central (CMT) e espessura da camada de fibra nervosa retiniana (RNFL). Métodos: 42 olhos de 42 pacientes que trataram com capsulotomia laser Nd: YAG foram incluídos neste estudo prospectivo. O equivalente esférico (SE), a refração de potência cíclica, a espessura CMT e RNFL foram avaliados pré-operatório e no primeiro dia pós-operatório, primeira semana e primeiro mês pós-operatório. Resultados: valores equivalentes esféricos e valores de espessura macular central não alteraram significativamente no primeiro mês após o tratamento. Os valores médios e da espessura da camada de fibra nervosa nasal da retina aumentaram significativamente e a refração do poder cíclico diminuiu significativamente durante as visitas. Conclusão: Nd: a capsulotomia laser YAG é uma opção de tratamento confiante e confiável da opacificação da cápsula posterior (PCO). Após Nd: a capsulotomia do laser YAG, a refração do poder cíclico e os valores da espessura do RNFL mudam significativamente.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Refração Ocular/fisiologia , Retina/diagnóstico por imagem , Lasers de Estado Sólido/uso terapêutico , Opacificação da Cápsula/cirurgia , Capsulotomia Posterior/métodos , Fibras Nervosas , Retina/anatomia & histologia , Acuidade Visual/fisiologia , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica , Terapia a Laser/métodos , Opacificação da Cápsula/etiologia
12.
Journal of the Korean Ophthalmological Society ; : 530-538, 2017.
Artigo em Coreano | WPRIM | ID: wpr-193505

RESUMO

PURPOSE: We compared the ocular aberration and clinical outcome between different aspheric intraocular lenses (IOL) in both eyes. METHODS: This prospective randomized controlled study was comprised of patients with bilateral cataract who received two different aspheric IOLs implanted in both eyes: negatively aspheric Tecnis® ZCB00 and spherically neutral Akreos® MI60. Total and corneal aberrations computed by Wavescan® and Pentacam® were assessed at 6 months to investigate the effects of the IOL's spherical aberration on the eye and to analyze the incidence and degree of posterior capsule opacification. By using spherical aberration of the cornea and the IOLs, values calculated via Ray-tracing software and Wavescan® were compared. Total spherical aberration was analyzed by the MATLAB program and converting the pupil size to 6.0, 4.5, 3.0 mm. RESULTS: A total of 25 patients were included. Regarding pre-operative corneal aberration, ZCB00 group was 0.232 ± 0.119 µm while MI60 group was 0.240 ± 0.117 µm, and there was no difference between the two IOLs. At 6 months after total ocular spherical aberration, MI60 group (pupil size 6.0 mm; 0.296 ± 0.097 µm, 4.5 mm; 0.094 ± 0.032 µm, 3.0 mm; 0.019 ± 0.006 µm) had more positive values than ZCB00 group (pupil size 6.0 mm; 0.051 ± 0.105 µm, 4.5 mm; 0.009 ± 0.034 µm, 3.0 mm; 0.002 ± 0.007 µm) (p < 0.001). When calculated using the ray tracing method, based on the results after surgery, MI60 group's total spherical aberrations were higher than ZCB00 group. However, from 1 month to 6 months after surgery, the uncorrected distance visual acuity, spherical equivalent and posterior capsule opacification showed no differences between the two IOLs. CONCLUSIONS: In eyes with aspheric IOLs with negative spherical aberration, spherical aberration was lower than spherically neutral aspheric IOLs. Regarding postoperative visual acuity, spherical equivalent and posterior capsule opacification, there were no significant differences between the two groups.


Assuntos
Humanos , Opacificação da Cápsula , Catarata , Córnea , Incidência , Lentes Intraoculares , Métodos , Estudos Prospectivos , Pupila , Acuidade Visual
13.
Yeungnam University Journal of Medicine ; : 111-114, 2017.
Artigo em Coreano | WPRIM | ID: wpr-84528

RESUMO

Central serous chorioretinopathy may induce poor eyesight and serous retinal detachment. However, its exact cause has not been well established thus far. It can be associated with systemic high-dose corticosteroid treatment mainly for young and middle-aged men and may spontaneously regress or recur after withdrawal from corticosteroid. After corticosteroid administration for Behcet's disease, it is necessary to identify any ocular symptoms. Behcet's disease can lead to the development of ocular complications, such as uveitis, hypopyon, retinal vasculitis, optic neuritis, angiogenesis, secondary cataract, and glaucoma. It is possible to diagnose any of these complications via optical coherence tomography and digital indocyanine green angiography. It is easy to neglect an ocular symptom that may appear after a low-dose corticosteroid treatment as an ocular complication in patients with Behcet's disease. Thus, we report on a case concerning high-dose corticosteroid treatment with a literature review.


Assuntos
Humanos , Masculino , Angiografia , Síndrome de Behçet , Opacificação da Cápsula , Coriorretinopatia Serosa Central , Glaucoma , Verde de Indocianina , Neurite Óptica , Descolamento Retiniano , Vasculite Retiniana , Tomografia de Coerência Óptica , Uveíte
14.
Korean Journal of Ophthalmology ; : 52-57, 2017.
Artigo em Inglês | WPRIM | ID: wpr-122714

RESUMO

PURPOSE: To evaluate the long-term visual outcomes and complications of cataract surgery in eyes previously treated for retinoblastoma. METHODS: We reviewed the medical records of patients who underwent cataract extraction and intraocular lens implantation at Seoul National University Children's Hospital for a secondary cataract that developed after retinoblastoma treatment. RESULTS: During the period between 1990 and 2014, 208 eyes of 147 patients received eye-salvaging treatment (radiotherapy, chemotherapy, and local therapy) for retinoblastoma at Seoul National University Children's Hospital. Among these eyes, a secondary cataract was detected in 17 eyes of 14 patients, and five eyes of five patients underwent cataract surgery. The median age of cataract formation was 97 months (range, 38 to 153 months). The medial interval between the diagnosis of retinoblastoma and cataract formation was 79 months (range, 29 to 140 months). All patients received posterior chamber intraocular lens insertion after irrigation and aspiration of the lens through a scleral tunnel incision. Anterior vitrectomy and posterior capsulotomy were performed in two eyes and a laser capsulotomy was subsequently performed in one eye. No intraoperative and postoperative complications occurred. The median follow-up after surgery was 36 months (range, 14 to 47 months). The final best corrected visual acuities were improved in all five eyes. No intraocular tumor recurrences or metastases occurred. CONCLUSIONS: After retinoblastoma regression, cataract extraction in our series was not associated with tumor recurrence or metastasis. Visual improvement was noted in every patient.


Assuntos
Humanos , Opacificação da Cápsula , Extração de Catarata , Catarata , Diagnóstico , Tratamento Farmacológico , Seguimentos , Implante de Lente Intraocular , Lentes Intraoculares , Prontuários Médicos , Metástase Neoplásica , Capsulotomia Posterior , Complicações Pós-Operatórias , Radioterapia , Recidiva , Retinoblastoma , Seul , Acuidade Visual , Vitrectomia
15.
Yeungnam University Journal of Medicine ; : 111-114, 2017.
Artigo em Coreano | WPRIM | ID: wpr-787038

RESUMO

Central serous chorioretinopathy may induce poor eyesight and serous retinal detachment. However, its exact cause has not been well established thus far. It can be associated with systemic high-dose corticosteroid treatment mainly for young and middle-aged men and may spontaneously regress or recur after withdrawal from corticosteroid. After corticosteroid administration for Behcet's disease, it is necessary to identify any ocular symptoms. Behcet's disease can lead to the development of ocular complications, such as uveitis, hypopyon, retinal vasculitis, optic neuritis, angiogenesis, secondary cataract, and glaucoma. It is possible to diagnose any of these complications via optical coherence tomography and digital indocyanine green angiography. It is easy to neglect an ocular symptom that may appear after a low-dose corticosteroid treatment as an ocular complication in patients with Behcet's disease. Thus, we report on a case concerning high-dose corticosteroid treatment with a literature review.


Assuntos
Humanos , Masculino , Angiografia , Síndrome de Behçet , Opacificação da Cápsula , Coriorretinopatia Serosa Central , Glaucoma , Verde de Indocianina , Neurite Óptica , Descolamento Retiniano , Vasculite Retiniana , Tomografia de Coerência Óptica , Uveíte
16.
Journal of the Korean Ophthalmological Society ; : 1063-1070, 2016.
Artigo em Coreano | WPRIM | ID: wpr-129364

RESUMO

PURPOSE: To compare neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy rates between hydrophobic and hydrophilic intraocular lenses. METHODS: The present retrospective study enrolled patients who received cataract surgery from a single surgeon between July 2006 to December 2009. Patients included in the study were implanted with SA60AT hydrophobic spherical intraocular lenses (Alcon, Fort Worth, TX, USA, 268 eyes) or I-FLEX hydrophilic spheric intraocular lenses (i-Medical®, Ophthalmic International Heidelberg GmbH, Mannheim, Germany, 331 eyes). The Nd:YAG capsulotomy rates and best-corrected visual acuity (BCVA) were compared between the two groups for 2 years after the operation. RESULTS: The mean follow-up period was 23.5 months and 22.6 months and the mean age was 68.6 years and 70.3 years in the SA60AT and I-FLEX groups, respectively. Follow-up periods were longer in the SA60AT group (p = 0.035), but ages were not significantly different between the two groups (p = 0.367). Nd:YAG laser capsulotomy rates were 6.3% in the SA60AT group and 11.2% in the I-FLEX group. Nd:YAG laser capsulotomy rates were significantly higher in the I-FLEX group (p = 0.020). BCVA before and after the Nd:YAG laser capsulotomy was not significantly different. CONCLUSIONS: Nd:YAG laser capsulotomy rates were higher in the I-FLEX hydrophilic spheric intraocular lens group than in the SA60AT hydrophilic spheric intraocular lens group. Adhesion between capsular bag and intraocular lens by bioadhesive character of hydrophobic acryl intraocular lens may contribute to the prevention of lens epithelial migration and posterior capsule opacification.


Assuntos
Humanos , Alumínio , Opacificação da Cápsula , Catarata , Seguimentos , Alemanha , Lentes Intraoculares , Estudos Retrospectivos , Acuidade Visual , Ítrio
17.
Journal of the Korean Ophthalmological Society ; : 1063-1070, 2016.
Artigo em Coreano | WPRIM | ID: wpr-129349

RESUMO

PURPOSE: To compare neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy rates between hydrophobic and hydrophilic intraocular lenses. METHODS: The present retrospective study enrolled patients who received cataract surgery from a single surgeon between July 2006 to December 2009. Patients included in the study were implanted with SA60AT hydrophobic spherical intraocular lenses (Alcon, Fort Worth, TX, USA, 268 eyes) or I-FLEX hydrophilic spheric intraocular lenses (i-Medical®, Ophthalmic International Heidelberg GmbH, Mannheim, Germany, 331 eyes). The Nd:YAG capsulotomy rates and best-corrected visual acuity (BCVA) were compared between the two groups for 2 years after the operation. RESULTS: The mean follow-up period was 23.5 months and 22.6 months and the mean age was 68.6 years and 70.3 years in the SA60AT and I-FLEX groups, respectively. Follow-up periods were longer in the SA60AT group (p = 0.035), but ages were not significantly different between the two groups (p = 0.367). Nd:YAG laser capsulotomy rates were 6.3% in the SA60AT group and 11.2% in the I-FLEX group. Nd:YAG laser capsulotomy rates were significantly higher in the I-FLEX group (p = 0.020). BCVA before and after the Nd:YAG laser capsulotomy was not significantly different. CONCLUSIONS: Nd:YAG laser capsulotomy rates were higher in the I-FLEX hydrophilic spheric intraocular lens group than in the SA60AT hydrophilic spheric intraocular lens group. Adhesion between capsular bag and intraocular lens by bioadhesive character of hydrophobic acryl intraocular lens may contribute to the prevention of lens epithelial migration and posterior capsule opacification.


Assuntos
Humanos , Alumínio , Opacificação da Cápsula , Catarata , Seguimentos , Alemanha , Lentes Intraoculares , Estudos Retrospectivos , Acuidade Visual , Ítrio
18.
Arq. bras. oftalmol ; 78(6): 344-347, Nov.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-768170

RESUMO

ABSTRACT Purpose: Optic coherence tomography (OCT) evaluation of the choroid, retina, and retinal nerve fiber layer after uncomplicated yttrium-aluminum-garnet (YAG) laser capsulotomy. Methods: OCT analysis of retinal and choroidal structures was performed in 28 eyes of 28 patients following routine examinations before and 24 h, 72 h, 2 weeks, 4 weeks, and 12 weeks after YAG laser capsulotomy. Data were analyzed using the SPSS software. Results: Data collected before YAG capsulotomy and at the above mentioned follow-up visits are summarized as follows. Mean central subfoveal choroidal thickness before YAG capsulotomy was 275.85 ± 74.78 µm; it was 278.46 ± 83.46 µm, 283.39 ± 82.84 µm, 280.00 ± 77.16 µm, 278.37 ± 76.95 µm, and 278.67 ± 76.20 µm after YAG capsulotomy, respectively. Central macular thickness was 272.14 ± 25.76 µm before YAG capsulotomy; it was 266.53 ± 26.47 µm, 269.14 ± 27.20 µm, 272.17 ± 26.97 µm, 270.91 ± 26.79 µm, and 273 ± 26.63 µm after YAG capsulotomy, respectively. Mean retinal nerve fiber layer thickness before YAG was 99.89 ± 7.61 µm; it was 98.50 ± 8.62 µm, 98.14 ± 8.69 µm, 99.60 ± 8.39 µm, 99.60 ± 8.39 µm, and 99.60 ± 8.35 µm after YAG capsulotomy, respectively. No observed change was statistically significant. No significant changes were observed with regard to mean intraocular pressure. Conclusions: After YAG laser capsulotomy, no statistically significant changes were found in choroidal, retinal, and optical nerve fiber layer thicknesses, although slight thickness changes in these structures were observed, particularly during the first days.


RESUMO Objetivo: Avaliação da coroide, retina e a camada de fibras nervosas da retina por meio de tomografia de coerência óptica (OCT) após capsulotomia por YAG laser não complicada. Método: Vinte e oito olhos de 28 pacientes foram incluídos neste estudo. Estruturas da retina e coroide foram analisados usando ACT nos exames de rotina antes da capsulotomia posterior por YAG laser e 24 horas, 72 horas, 2 semanas, 4 semanas e 12 semanas após YAG. Os resultados foram avaliados através do programa SPSS. Resultados: Os resultados deste estudo, pré YAG e às visitas de acompanhamento acima, podem ser resumidos da seguinte forma. A espessura média de coroide subfoveal central antes do YAG foi 275,85 ± 74,78 m; após YAG foi 278,46 ± 83,46 µm, 283,39 ± 82,84 µm, 280,00 ± 77,16 µm, 278,37 ± 76,95 µm, e 278,67 ± 76,20 µm, respectivamente. A espessura macular central foi 272,14 ± 25,76 mm antes YAG; e 266,53 ± 26,47 µm, 269,14 ± 27,20 µm, 272,17 ± 26,97 µm, 270,91 ± 26,79 µm, e 273 ± 26,63 µm, respectivamente. Espessura média da camada de fibras nervosas da retina antes do YAG foi 99,89 ± 7,61 mm; e 98,50 ± 8,62 µm, 98,14 ± 8,69 µm, 99,60 ± 8,39 µm, de 99,60 ± 8,39 µm, 99,60 ± 8,35 µm, respectivamente. Nenhuma das alterações observadas foram estatisticamente significativas. As médias da pressão intraocular, também não mostraram alterações significativas. Conclusões: Não houve mudanças significativas foram encontradas na coroide, camada de fibras nervosas da retina espessuras e ópticos, após a capsulotomia por YAG laser, embora houvesse, especialmente nos primeiros dias, discretas alterações de espessura nas estruturas mencionadas.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Corioide/patologia , Lasers de Estado Sólido/uso terapêutico , Capsulotomia Posterior/métodos , Retina/patologia , Tomografia de Coerência Óptica/métodos , Análise de Variância , Opacificação da Cápsula/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Facoemulsificação/efeitos adversos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
19.
Arq. bras. med. vet. zootec ; 67(5): 1295-1303, tab, graf
Artigo em Português | LILACS | ID: lil-764442

RESUMO

O objetivo deste estudo foi avaliar o efeito do tratamento da superfície de lentes intraoculares acrílicas utilizando-se plasma de flúor ou polietilenoglicol na prevenção da opacidade de cápsula posterior. Foram analisados 40 olhos de coelhos, submetidos à cirurgia de facoemulsificação e distribuídos em quatro grupos experimentais (n=10), sendo estes: grupo controle, coelhos sem implante de lente intraocular; grupo com lente intraocular tratada com plasma de polietilenoglicol; grupo com lente intraocular tratada com plasma de flúor; e grupo com lente intraocular comercial. As cápsulas posteriores das lentes dos grupos foram avaliadas por meio de análise histopatológica (morfometria e imuno-histoquímica). Os grupos com lente intraocular tratada com polietilenoglicol e com lente intraocular comercial apresentaram menor espessura da cápsula posterior na avaliação inicial (12 semanas) em relação ao grupo controle. No período final de avaliação (6 meses), os tratamentos da superfície da lente intraocular à base de plasma de flúor e polietilenoglicol não reduziram o desenvolvimento das alterações histológicas associadas à opacidade de cápsula posterior. O tratamento das superfícies das lentes intraoculares com plasma de flúor e polietilenoglicol pode ser realizado como adjuvante na prevenção da opacidade de cápsula posterior, pois não causa alterações na morfologia da lente após facoemulsificação.


The aim of this study was to evaluate the effect of surface treatment of acrylic intraocular lens using Fluorine plasma or polyethylene glycol in the prevention of posterior capsule opacification. Forty rabbit eyes that underwent phacoemulsification were analyzed and distributed into four experimental groups (n=10): Control group, composed of rabbits without intraocular lens implantation; intraocular lens group treated with Polyethylene glycol plasma, intraocular lens group treated with Fluoride plasma, and commercial intraocular lens group. The posterior capsule of the lens was evaluated by histopathological analysis, including morphometric and immunohistochemical studies. Groups with intraocular lens treated with polyethylene glycol and commercial intraocular lens presented thinner posterior capsule at initial assessment (12 weeks) compared to the control group. At the end of the evaluation (six months), the treatment of surface intraocular lens with fluorine and polyethylene glycol plasma did not reduce the development of histological changes associated with posterior capsule opacification. The surface treatment of the intraocular lens with Fluoride and Polyethylene glycol can be performed as an adjuvant in preventing posterior capsule opacification, because it does not cause changes in the morphology of lens after phacoemulsification surgery.


Assuntos
Animais , Coelhos , Opacificação da Cápsula , Olho , Lentes Intraoculares/efeitos adversos , Facoemulsificação , Histologia , Imuno-Histoquímica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA